9.9 Oxygen Lance

Ⅰ Dominant Items

9.9.1 The hydrostatic test of oxygen lance must meet the requirement of the design technical document.

Quantity to be checked:100%.

Inspection method:Observe,and check the pressure test record.

9.9.2 The parts,components and pipeline of the equipment contact with oxygen must not be stained with oil or grease.

Quantity to be checked:100%.

Inspection method:Check the record of degreasing,and check via wiping with white filter paper or exposing it under the ultraviolet lamp.

Ⅱ General Items

9.9.3 The allowable deviation for installation of oxygen lance shall comply with the requirements in Table 9.9.3.

Quantity to be checked:100%.

Inspection method:See Table 9.9.3.

Table 9.9.3 Allowable deviation for installation of oxygen lance